{"id":35,"date":"2026-10-04T07:31:58","date_gmt":"2026-10-04T07:31:58","guid":{"rendered":"https:\/\/ruraopticalsystems.com\/?page_id=35"},"modified":"2026-10-04T07:31:58","modified_gmt":"2026-10-04T07:31:58","slug":"photonmetra-p100","status":"publish","type":"page","link":"https:\/\/ruraopticalsystems.com\/?page_id=35","title":{"rendered":"PhotonMetra P100"},"content":{"rendered":"\n<div class=\"wp-block-columns alignwide is-layout-flex wp-container-core-columns-is-layout-794e3cfa wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:66.66%\">\n<h2 class=\"wp-block-heading\">Portable First-Surface Reflectance &amp; Thin Film Analyzer<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Measure the coating \u2014 not the back surface.<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The PhotonMetra P100 is a portable and stand-alone spectroscopic measurement system for quantitative first-surface reflectance analysis of coated glass and transparent plastic substrates.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Operating over <strong>250\u20131100 nm<\/strong>, the fiber-optic measurement system selectively measures the reflection from the first air\u2013substrate interface while minimizing contributions from the rear surface.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">With measurement geometries of <strong>15\u00b0 and 30\u00b0<\/strong>, the PhotonMetra P100 is designed for both laboratory and production environments.<\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:33.33%\">\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"613\" src=\"https:\/\/ruraopticalsystems.com\/wp-content\/uploads\/2026\/09\/thin-film-analyser-1024x613.png\" alt=\"\" class=\"wp-image-36\" srcset=\"https:\/\/ruraopticalsystems.com\/wp-content\/uploads\/2026\/09\/thin-film-analyser-1024x613.png 1024w, https:\/\/ruraopticalsystems.com\/wp-content\/uploads\/2026\/09\/thin-film-analyser-300x180.png 300w, https:\/\/ruraopticalsystems.com\/wp-content\/uploads\/2026\/09\/thin-film-analyser-767x459.png 767w, https:\/\/ruraopticalsystems.com\/wp-content\/uploads\/2026\/09\/thin-film-analyser.png 1442w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n<\/div>\n<\/div>\n\n\n\n<div style=\"height:80px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h2 class=\"wp-block-heading\">Key Features<\/h2>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-794e3cfa wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<h3 class=\"wp-block-heading\">250-1100 nm<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">UV\u2013VIS\u2013NIR spectral range<\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<h3 class=\"wp-block-heading\">First-Surface Reflectance<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Minimized rear-surface contribution<\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<h3 class=\"wp-block-heading\">15\u00b0 &amp; 30\u00b0 Measurement<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Improved front- and rear-surface separation for thinner glass<\/p>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-794e3cfa wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<h3 class=\"wp-block-heading\">Glass &amp; Transparent Plastics<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Suitable for coated transparent substrates<\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<h3 class=\"wp-block-heading\">Laboratory &amp; Production<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">For R&amp;D, process control and quality assurance<\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<h3 class=\"wp-block-heading\">Portable &amp; Stand-Alone<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Integrated computer and display<\/p>\n<\/div>\n<\/div>\n\n\n\n<div style=\"height:80px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Why First-Surface Measurement?<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Measure the coating itself \u2014 not the complete glass substrate.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">On transparent substrates, conventional reflectance measurements may contain contributions from both the front and rear surfaces. The PhotonMetra P100 uses a defined fiber-optic measurement geometry to isolate the first-surface reflection and strongly suppress the rear-surface contribution.<\/p>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-794e3cfa wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<h3 class=\"wp-block-heading\">How it works<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>The PhotonMetra P100 uses a defined illumination and detection geometry to spatially separate the reflection from the front surface from the reflection originating at the rear surface of the transparent substrate. By positioning the illumination and detection optics at a controlled angle, the two reflected beams follow different optical paths. The detector is aligned to collect the first-surface reflection while strongly suppressing the contribution from the rear surface.<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Substrate thickness is an important parameter because it determines the spatial separation between the front- and rear-surface reflections. For glass thicknesses of approximately 3 mm and above, the standard 15\u00b0 measurement geometry is recommended. For thinner glass, the 30\u00b0 geometry provides greater separation between the two reflections and can typically extend first-surface measurement capability down to glass thicknesses of approximately 1.5 mm.<\/strong><\/p>\n<\/div>\n<\/div>\n\n\n\n<h2 class=\"wp-block-heading\">Measurement Modes<\/h2>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-794e3cfa wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<h3 class=\"wp-block-heading\"><strong>First-Surface Reflectance<\/strong><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">The PhotonMetra P100 is primarily designed for first-surface reflectance measurement, isolating the reflection from the front surface while strongly suppressing the contribution from the rear surface. Measurements can be performed at 15\u00b0 and 30\u00b0. The 30\u00b0 geometry increases the spatial separation between the front- and rear-surface reflections, extending first-surface measurement capability to thinner transparent substrates.<\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<h3 class=\"wp-block-heading\"><strong>Total Reflectance<\/strong><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">FFor very thin transparent substrates, the front- and rear-surface reflections may no longer be reliably separated. In these cases, the PhotonMetra P100 can operate in Total Reflectance mode, measuring the combined reflectance of the complete transparent substrate. This mode is suitable for thin glass and transparent polymer substrates. It is also useful when the total optical response of the complete component is more relevant than the reflectance of an individual surface.<\/p>\n<\/div>\n<\/div>\n\n\n\n<h2 class=\"wp-block-heading\">Typical Applications<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Solar Glass Production Control<\/strong><br><strong>Coated Glass Inspection<\/strong><br><strong>Display &amp; Cover Glass<\/strong><br><strong>Transparent Plastics<\/strong><br><strong>Thin-Film Development<\/strong><br><strong>Production Spot Checks<\/strong><\/p>\n\n\n\n<h3 class=\"wp-block-heading\">S<strong>olar Glass Production Control<\/strong><br>Portable first-surface reflectance measurement for coated solar glass, enabling rapid verification of AR coating performance directly in the production environment. Measurements can be performed at different positions on the glass to evaluate coating consistency and support process and quality control.<\/h3>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>Coated Glass Inspection<\/strong><br>Portable first-surface reflectance measurement directly on coated glass, without requiring small laboratory samples. Suitable for coating development, incoming inspection and production quality control.<\/h3>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>Display &amp; Cover Glass<\/strong><br>Measurement of anti-reflection and other optical coatings on display and cover glass, where the reflectance of the coated front surface is the relevant parameter.<\/h3>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>Transparent Plastics<\/strong><br>First-surface or total-reflectance measurement on transparent polymer substrates and coated plastics, depending on substrate thickness and measurement requirements.<\/h3>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>Thin-Film Development<\/strong><br>Spectral first-surface reflectance data can be used to compare coating designs, evaluate process changes and support thin-film optical analysis during coating development.<\/h3>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>Production Spot Checks<\/strong><br>The portable stand-alone design allows measurements to be performed directly at different locations in the laboratory or production environment, supporting rapid comparison of coating performance across samples or production batches.<\/h3>\n\n\n\n<h2 class=\"wp-block-heading\">Portable &amp; Stand-Alone Operation<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>The PhotonMetra P100 is designed as a portable stand-alone measurement system with an integrated computer and display. Measurements, data review and basic analysis can therefore be performed directly at the measurement location without requiring a separate external PC.<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>The system is suitable for both laboratory use and production environments. Touchscreen operation is supported, while a keyboard and mouse can also be connected when preferred.<\/strong><\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Technical Specifications<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">View the detailed technical specifications for the PhotonMetra P100.<\/p>\n\n\n\n<div class=\"wp-block-buttons is-layout-flex wp-block-buttons-is-layout-flex\">\n<div class=\"wp-block-button\"><a class=\"wp-block-button__link wp-element-button\" href=\"https:\/\/ruraopticalsystems.com\/?page_id=79\">View Technical Specifications<\/a><\/div>\n<\/div>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Portable First-Surface Reflectance &amp; Thin Film Analyzer Measure the coating \u2014 not the back surface. The PhotonMetra P100 is a portable and stand-alone spectroscopic measurement system for quantitative first-surface reflectance analysis of coated glass and transparent plastic substrates. Operating over 250\u20131100 nm, the fiber-optic measurement system selectively measures the reflection from the first air\u2013substrate interface [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"footnotes":""},"class_list":["post-35","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/ruraopticalsystems.com\/index.php?rest_route=\/wp\/v2\/pages\/35","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/ruraopticalsystems.com\/index.php?rest_route=\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/ruraopticalsystems.com\/index.php?rest_route=\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/ruraopticalsystems.com\/index.php?rest_route=\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/ruraopticalsystems.com\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=35"}],"version-history":[{"count":2,"href":"https:\/\/ruraopticalsystems.com\/index.php?rest_route=\/wp\/v2\/pages\/35\/revisions"}],"predecessor-version":[{"id":82,"href":"https:\/\/ruraopticalsystems.com\/index.php?rest_route=\/wp\/v2\/pages\/35\/revisions\/82"}],"wp:attachment":[{"href":"https:\/\/ruraopticalsystems.com\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=35"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}